Customer questions and answers

  1. 0 votes
    R

    That valve cannot be disassembled, and as far as we know, it cannot be cleaned. 

  2. 0 votes
    R

    If the micro-sprinklers do not start working, you should check two things mainly, firstly, check the dynamic pressure of the water you have in your house, this is done by opening a tap in the house and putting a pressure gauge on another tap in the house.

    If the pressure gauge of the second tap does not read above 2.5atm, the AD20 valves will not work since they open from 2atm.

    On the other hand, you must control the flow of the installed micro-sprinklers since if you have them connected to a household tap, it will not supply more than 700-800 l / h approximately, if all the micro-sprinklers demand more flow, the system will not work since there is no flow. to work all, in this case you will have to sectorize the irrigation in several shifts.

     

    We hope we have been helpful.

    Any questions please contact us. 655 96 81 54

     

    Sincerely,

    The Mundoriego Team.

Send me a notification for each new answer.